Caída de presión por fricción durante el flujo de condensación en el interior de mini/microcanales: evaluación de herramientas predictivas y tratamiento de datos
Frictional pressure drop during condensing flow inside mini/micro-channels: predictive tools assessment and data treatment
DOI:
https://doi.org/10.6036/10750Keywords:
Two-phase flow frictional pressure gradient, Mini/ micro-channels, Condensing flow, New refrigerant fluid, Heat transfer, Collect database, low-GWP, refrigerant, pressure drop, condensing.Abstract
A total of 1210 new condensation friction pressure gradient points (database) is collected from 12 open articles on mini/
micro-channels literature. The database covered a wide range of thermophysical properties associated with low-GWP
refrigerants, physical dimension, mass velocity and vapor quality. A comparison of the experimental database against
eleven two-phase flow frictional pressure drop prediction tools is carried out. Based on that, the mini/micro-channel
developed by Xu and Fang exhibited the best ability to capture the tendency of the database with a mean absolute relative
deviation of (36.59%) for all data.
Downloads
Published
License

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.